11QE65 - Laser Energy Detectors

Laser Energy Detectors
 
Modular Concept
Increase the power capability of your detector with 2 different cooling modules
Low Noise Level
10 µJ for the MT coating
QED Attenuator Available
Measure up to 5X higher energies. Available with optional calibration, all wavelengths between 532 & 1064 nm, or single wavelength
Large Aperture
Effective aperture of 65 x 65 mm
Test Target Included
With the MB models
Smart Interface
Containing all the calibration data
 

11QE65 laser energy detectors can measure energy up to 200 J (with attenuator). Low noise level - just 10 µJ. Large effective aperture - 65 mm square. These detectors are convenient to use and can measure relatively wide beams. They are suitable for many OEM, manufacturing and laboratory applications.

Specifications
Detector 11QE65LP-S-MB 11QE65LP-H-MB 11QE65ELP-S-MB 11QE65ELP-H-MB
MAX MEASURABLE ENERGY (WITH ATTENUATOR) 200 J 200 J 200 J 200 J
MAX REPETITION FREQUENCY 100 Hz 100 Hz 20 Hz 20 Hz
EFFECTIVE APERTURE 65 x 65 mm 65 x 65 mm 65 x 65 mm 65 x 65 mm
MEASUREMENT CAPABILITY
Spectral Range *a 0.19 – 20 µm 0.19 – 20 µm 0.19 – 20 µm 0.19 – 20 µm
Maximum Measurable Energy b,c Alone Attenuator Alone Attenuator Alone Attenuator Alone Attenuator
   1064 nm, 150 ns pulse, single shot d 50 J 200 J 50 J 200 J 50 J 200 J 50 J 200 J
   1064 nm, 7 ns, 10 Hz 25 J 125 J 25 J 125 J 25 J 125 J 25 J 125 J
   266 nm, 7 ns, 10 Hz 20 J 35 J 20 J 35 J 20 J 35 J 20 J 35 J
Noise Equivalent Energy e 10 µJ 10 µJ 20 µJ 20 µJ
Sensitivity f,g 4 V/J 4 V/J 1.5 V/J 1.5 V/J
Max Repetition Frequency 100 Hz 100 Hz 20 Hz 20 Hz
Maximum Pulse Width (typical) 0.7 ms 0.7 ms 5 ms 5 ms
Rise Time (typical 0-100 %) 1 ms 1 ms 6 ms 6 ms
Calibration Uncertainty h ±3 % ±3 % ±3 % ±3 %
Repeatability <3 % <3 % <3 % <3 %
DAMAGE THRESHOLDS
Maximum Average Power Alone Attenuator Alone Attenuator Alone Attenuator Alone Attenuator
   All Wavelengths 12 W 30 W 40 W 90 W 12 W 30 W 40 W 90 W
Maximum Energy Density Alone Attenuator Alone Attenuator Alone Attenuator Alone Attenuator
   1064 nm, 150 µs, 10 Hz 1.2 J/cm2 14 J/cm2 1.2 J/cm2 14 J/cm2 1.2 J/cm2 14 J/cm2 1.2 J/cm2 14 J/cm2
   1064 nm, 7 ns, single shot 0.6 J/cm2 16 J/cm2 0.6 J/cm2 16 J/cm2 0.6 J/cm2 16 J/cm2 0.6 J/cm2 16 J/cm2
   1064 nm, 7 ns, 10 Hz 0.6 J/cm2 8 J/cm2 0.6 J/cm2 8 J/cm2 0.6 J/cm2 8 J/cm2 0.6 J/cm2 8 J/cm2
   532 nm, 7 ns, 10 Hz 0.6 J/cm2 6 J/cm2 0.6 J/cm2 6 J/cm2 0.6 J/cm2 6 J/cm2 0.6 J/cm2 6 J/cm2
   266 nm, 7 ns, 10 Hz 0.5 J/cm2 1 J/cm2 0.5 J/cm2 1 J/cm2 0.5 J/cm2 1 J/cm2 0.5 J/cm2 1 J/cm2
Maximum Average Power Density 10 W/cm2 600 W/cm2 10 W/cm2 i 600 W/cm2 10 W/cm2 600 W/cm2 10 W/cm2 i 600 W/cm2
PHYSICAL CHARACTERISTICS
Effective Aperture (with Attenuator) 65 X 65 mm (62 X 62 mm)
Absorber Multi-Band Multi-Band Multi-Band Multi-Band
Dimensions 90H x 90W x 20D mm 90H x 90W x 94D mm 90H x 90W x 20D mm 90H x 90W x 94D mm
Weight 440 g 900 g 440 g 900 g
Specifications are subject to change without notice

* For the calibrated spectral range, see the user manual.
a. 0.308 - 2.1 µm with QED Attenuator.
b. Not exceeding Maximum Average Power.
c. Maximum measurable energy depends on the monitor.
d. Increasing pulse width increases the maximum measurable energy.
e. Nominal value, actual value depends on electrical noise in the measurement system.
f. Load: 1 M&Omh; and ≤ 30 pF.
g. Maximum output voltage = sensitivity x maximum energy.
h. Excludes non-linearities.
i. At 12 W. Maximum Average Power Density is 5 W/cm2 @ 40 W.

More information about QED attenuators

Compatible Monitors:


11MAESTRO

11M-LINK

11S-LINK
 
Ordering Information
Model Details
11QE65ELP-H-MB
11QE65ELP-H-MB-QED with attenuator
11QE65ELP-S-MB
11QE65ELP-S-MB-QED with attenuator
11QE65LP-H-MB
11QE65LP-H-MB-QED with attenuator
11QE65LP-S-MB
11QE65LP-S-MB-QED with attenuator
 


Laser Energy Detectors