Active Vibration Isolation System
Active Vibration Isolation System
Active Vibration Isolation System
 
Advanced products search 
Products
 
Opto-Mechanical Products
Optical Tables
Brackets & Rails
Base Mounts & Accessories
Optical Mounts
Optical Positioners
Base Positioners
Translation & Rotation Stages
Motorized Positioners & Controllers
Fine Adjustment Screws
Opto-Mechanics
Custom Engineering
Optics, Lasers & Measurement
Optics
Lasers & Laser Accessories
Light Test & Measurement Instruments
Spectroscopic Instruments
Spectrographs & Monochromators
Product Index
Product Search
New Products
My Links
My WishList
Catalog Request
My Account
User Name:
Password:
Remember login
Restore password | Register account
 
My WishList
There are no products in the WishList.
Submit Inquiry
edit WishList
help
 
STANDA in Lithuania
STANDA  P.O. BOX 377 , 03012 Vilnius, Lithuania
Phone +370 5 2651474, Fax +370 5 2651483
E-mail: sales@standa.LT
   
Standa in the World
   
 
1TS-AVI350LP - Active Vibration Isolation System New!
Active Vibration Isolation System
Zoom in
Printable version
Download PDF
 

1TS-AVI350LP, a compact modular dynamic antivibration system offering isolation against all six translational and rotational vibrations. This moderately priced dynamic vibration isolation system achieves in a very small volume better isolation than is possible with the biggest and most expensive passive systems. Inertial feedback is used via force transducers to provide not only isolation from building vibrations, but also isolation from vibration sources placed on the system itself. This means, for example, that a delicate microscope isolated by the system will remain at rest despite forces being applied via the operator’s hands. The inherent stiffness of the system, typically 500 times greater than that of a 1 Hz resonance passive isolator, imparts excellent directional and positional stability. The lack of any low frequency resonance, a resonance which plagues all passive systems, allows the systems to be stacked for super-isolation in severe environments. The system is ideal for supporting delicate Fabry- Perot interferometers and tunnel-microscopes, allowing the ultimate performance to be achieved from these and other high resolution instruments. The tables have also proved to be extremely successful for supporting sensitive experiments, such as the troughs for liquids used in measurements on Langmuir-Blodgett films. 1TS-AVI350LP is an adaptable system consisting of two modules. Each module by itself isolates against vertical and horizontal translations and against rotations about one horizontal axis. The combination of two modules isolates against all six possible translational and rotational vibrations. The modules cannot be used separately. Isolation of the standard 1TS-AVI350LP system begins at about 1 Hz, increasing rapidly to at least 35 dB beyond 10 Hz. This system offers excellent isolation in the typical laboratory environment.


1TS-AVI350LP with a standard honeycomb board for loads 0-350 kg. (Loads up to 200 kg per unit)
1TS-AVI350LP with a standard honeycomb board and with 1TS Table Suports

Vertical Zoom in

Horizontal Zoom in
 
Specifications
Isolation Dynamic 1Hz to 200 Hz, passive beyond 200 Hz
Transmissibility See transmission curve. Above 10 Hz transmissibility <0.017 decreasing rapidly beyond 100 Hz, depending on load
Correction forces Maximal ±8 N vertically, ±4 N horizontally
Static Compliance Approx. 3.5 μm/N vertically, 7 μm/N horizontally
System noise Less than 50 nG/vHz from 0.1 - 200 Hz in any direction
Static Load Minimum 0 kg, maximum 200 kg on each element
Self-weight 10 kg (per isolation unit)
Control Unit
Safety class 1
Power consumption Typically 7 W, maximum 9 W
Input voltage 110-230 V AC±10%, 50-60 Hz
Fuses 2x1.6 A/250V slow, located in the power socket on the rear side of the unit
Overload Indication 8 LEDs
Monitor Signal A multiplexed signal can be used via the BNC-socket at the rear panel of the control unit to display it on an oscilloscope. It shows the vibration levels with and without isolation
Top
Size The units should be arranged parallel to each other and may be spaced any distance from each other provided that the top plate is sufficiently rigid. The width of the top plate should not be more than about 1.5 times the length of the isolation units
Material Solid aluminium 20-30 mm thick or honeycomb material
Models