11UP25 - Laser Power Detector

Laser Power Detector
 
Modular Concept
Increase the power capability of your detector: 4 different cooling modules
High Performance
Fast Rise Time (1.3 sec), High Damage Threshold (45 kW/cm2)
Compact Design (T version)
Only 62.4 x 62.4 mm front and 38.1 mm thick for up to 250 W continuous power
Energy Mode
Measure single shot energy up to 40 J
Smart Interface
Containing all the calibration data
 
Specifications
Model 11UP25N-40S-H9 11UP25N-100H-H9 11UP25N-250F-H12 11UP25M-350W-H12 11UP25T-15S-H12 11UP25T-250W-H12
MAX AVERAGE POWER (CONTINUOUS / 1 MINUTE) 40 W / 80 W 100 W / 200 W 250 W / 300 W 350 W f / 350 W f 15 W / 15 W 250 W f / 250 W f
EFFECTIVE APERTURE 25 mm Ø 25 mm Ø 25 mm Ø 25 mm Ø 25 mm Ø 25 mm Ø
COOLING METHOD Convection Heatsink Fan-Cooled Water-Cooled Convection Water-Cooled
MEASUREMENT CAPABILITY
Spectral Range * 0.19 – 20 µm 0.19 – 20 µm 0.19 – 20 µm 0.19 – 20 µm 0.19 – 20 µm 0.19 – 20 µm
Noise Equivalent Power a 3 mW 3 mW 10 mW 10 mW 10 mW 10 mW
Rise Time (nominal) b 1.3 sec 1.3 sec 1.3 sec 1.3 sec 1.3 sec 1.3 sec
Sensitivity (typ into 100 k Ω load) c 0.23 mV/W 0.23 mV/W 0.1 mV/W 0.1 mV/W 0.1 mV/W 0.1 mV/W
Calibration Uncertainty d ±2.5 % ±2.5 % ±2.5 % ±2.5 % ±2.5 % ±2.5 %
Repeatability ±0.5 % ±0.5 % ±0.5 % ±0.5 % ±0.5 % ±0.5 %
Energy Mode
   Sensitivity 0.14 mV/J 0.14 mV/J 0.05 mV/J 0.05 mV/J 0.05 mV/J 0.05 mV/J
   Maximum Measurable Energy e 40 J 40 J 40 J 40 J 40 J 40 J
   Noise Equivalent Energy a 0.2 J 0.2 J 0.2 J 0.2 J 0.2 J 0.2 J
   Minimum Repetition Period 4.6 sec 4.6 sec 11.5 sec 11.5 sec 11.5 sec 11.5 sec
   Maximum Pulse Width 123 ms 123 ms 390 ms 390 ms 390 ms 390 ms
   Accuracy with energy calibration option ±5 % ±5 % ±5 % ±5 % ±5 % ±5 %
DAMAGE THRESHOLDS
Maximum Average Power Density
   1064 nm, 10 W, CW 45 kW/cm2 45 kW/cm2 45 kW/cm2 45 kW/cm2 45 kW/cm2 45 kW/cm2
   10.6 µm, 10 W, CW 14 kW/cm2 14 kW/cm2 14 kW/cm2 14 kW/cm2 14 kW/cm2 14 kW/cm2
Pulsed Laser Damage Thresholds Max Energy Density Peak Power Density
   1064 nm, 360 µs, 5 Hz 9 J/cm2 25 kW/cm2
   1064 nm, 7 ns, 10 Hz 1 J/cm2 143 MW/cm2
   532 nm, 7 ns, 10 Hz 0.6 J/cm2 86 MW/cm2
   266 nm, 7 ns, 10 Hz 0.3 J/cm2 43 MW/cm2
PHYSICAL CHARACTERISTICS
Effective Aperture 25 mm Ø 25 mm Ø 25 mm Ø 25 mm Ø 25 mm Ø 25 mm Ø
Absorber (High Damage Threshold) H9 H9 H12 H12 H12 H12
Dimensions 89H x 89W x 32D mm 89H x 89W x 106D mm 89H x 89W x 116D mm 89H x 89W x 40D mm 62.4H x 62.4W x 38.1D mm 62.4H x 62.4W x 38.1D mm
Weight (head only) 0.68 kg 0.99 kg 1.44 kg 0.87 kg 0.31 kg 0.33 kg
Specifications are subject to change without notice

* For the calibrated spectral range, see the user manual.
a. Nominal value, actual value depends on electrical noise in the measurement system.
b. With STANDA 11MAESTRO, 11UNO, 11P-LINK, 11TUNER and 11S-LINK monitors.
c. Maximum output voltage = sensitivity x maximum power.
d. Including linearity with power.
e. For 360 µs pulses. Higher pulse energy possible when customized for long pulses (ms), less for short pulses (ns).
f. Minimum cooling flow 1.5 liters/min, water temperature ≤ 22°C, 1/8 NPT compression fittings for 1/4 inch semi-rigid tube. Contact STANDA for clean deionized water cooling module option.

Compatible Monitors:


11MAESTRO

11UNO

11TUNER

11M-LINK

11P-Link

11S-LINK
 
Ordering Information
Model
11UP25M-350W-H12
11UP25N-100H-H9
11UP25N-250F-H12
11UP25N-40S-H9
11UP25T-15S-H12
11UP25T-250W-H12
 


Laser Power Detector